Pressure capability guidelines:

There are many gaskets materials type, and the pressure ability to withstand for each materials type is different. It starts from low pressure for soft gasket material up to high pressure for metallic and semi-metallic gaskets. So, according to the pressure level high or low we need choose the right gasket material to create a reliable seal. The chart below provides a guide to the suitability of our materials in standard ANSI flanges.

Note: It should be noted that the ability to withstand assembly load is also dependent on the temperature of the application, and therefore gasket selection must be cheked with the pressure/temperature graphs given for each material.

We use Klinger reference of material styles because those are the ones we know best.

Materials

Class 150

(20 bar)

Class 300

(50 bar)

Class 600

(100 bar)

Class 900

(155 bar)

Class 1500

(260 bar)

Class 2500

(430 bar)

Rubber

×

×

×

×

×

Klingersil C-8200

×

×

×

×

Klingersil C-4324, C-4400

×

×

×

×

Klinger Quantum

Klinger top-sil-ML1

Klingersil C-4430, C-4500

×

×

×

Top-chem-2000

×

×

×

Top-chem-2003

×

×

×

×

Graphite laminate

×

×

×

Semi-Metallic


Reference: https://www.saidi.es/PDF/Corporate/SAIDI_PRODUCTS_CATALOGUE/SAIDI_CAT_SELLADO_ENG.pdf



Directives de capacité de pression :

Il existe de nombreux types de matériaux de joints d’étanchéité et la capacité de supporter la pression est différente pour chaque type de matériau. Cela va de la basse pression pour les matériaux de joint souples à la haute pression pour les joints métalliques et semi-métalliques. Ainsi, selon le niveau de pression élevé ou faible, nous devons choisir le bon matériau de joint pour créer un joint fiable. Le tableau ci-dessous fournit un guide sur l'adéquation de nos matériaux dans les brides ANSI standard.

Remarque : Il convient de noter que la capacité de résister à la charge d'assemblage dépend également de la température de l'application, et par conséquent, la sélection du joint doit être vérifiée avec les graphiques de pression/température donnés pour chaque matériau.

Nous utilisons la référence des styles de matériaux Klinger car ce sont ceux que nous connaissons le mieux.

Matériaux

Classe 150

(20 bar)

Classe 300

(50 bar)

Classe 600

(100 bar)

Classe 900

(155 bar)

Classe 1500

(260 bar)

Classe 2500

(430 bar)

Caoutchouc

×

×

×

×

×

Klingersil C-8200

×

×

×

×

Klingersil C-4324, C-4400

×

×

×

×

Klinger Quantum

Klinger top-sil-ML1

Klingersil C-4430, C-4500

×

×

×

Top-chem-2000

×

×

×

Top-chem-2003

×

×

×

×

Stratifié graphite

×

×

×

Semi-Métallique


Réference: https://www.saidi.es/PDF/Corporate/SAIDI_PRODUCTS_CATALOGUE/SAIDI_CAT_SELLADO_ENG.pdf

Comments

Popular posts from this blog

Which Removable Insulation Cover Materials to chose?

Flexible, removable insulation covers find application in heavy industries where swift or regular access to equipment is essential. These covers are crucial for insulating heat (or cold) to ensure safety, energy efficiency, and precision in industrial processes. A common inquiry revolves around the choice of fabric under specific circumstances. One pivotal factor to contemplate is whether the material is in direct contact with the equipment or exposed to external elements.   Presented below is a Decision Table to assist you in making informed choices:   Link We hope this table will facilitate your choice next time you require flexible removable cover insulation. Call Robco or Prodimax if you need further information.

Que signifie "Fire-Safe" pour le choix d'un joint d'étanchéité ?

 Dans le processus de sélection des matériaux de joints, de nombreuses questions portent sur le terme "sécurité incendie". Examinons brièvement les deux méthodes d'essai au feu les plus couramment utilisées pour les joints : API 6FA ET API 607. API 6FA : Le test 6FA-re de l'American Petroleum Institute est utilisé pour qualifier les vannes destinées aux procédés chimiques. La bride est assemblée selon les procédures de boulonnage appropriées et tous les paramètres tels que la contrainte et le couple sont enregistrés. Des thermocouples sont montés à 1 pouce de l'extérieur de la bride (figure 1). La vanne est enveloppée d'une flamme à l'aide de quatre brûleurs au propane disposés symétriquement autour de l'extérieur de la bride. La température de la flamme doit être comprise entre 1400ºF et 1800ºF (moyenne des deux thermocouples) pendant une période de combustion de 30 minutes à partir de l'allumage. La température est maintenue et aucune valeur n...

What does Fire-Safe mean when choosing a Gasket?

  In the process of gasket material selection, many inquiries point to the term “fire-safe”. Lets briefly look at the two most commonly used gasket fire testing methods: API 6FA & API 607. API 6FA: The American Petroleum Institute’s 6FA-re test is used to qualify valves for chemical process service.  The flange is assembled using proper bolt-up procedures and all parameters such as stress and torque are recorded. Thermocouples are mounted 1” away from the outside of the flange (Figure 1). The valve is enveloped in flame using four propane burners arranged symmetrically around the outside of the flange. The flame temperature should be 1400ºF to 1800ºF (average of the two thermocouples) for a burn period of 30 minutes from ignition. The temperature is maintained with no reading less than 1300ºF. An internal water pressure amounting to 75% of the flange rating is applied throughout the test and the leakage rate is continually measured. The test rig is then allowed t...