Skip to main content

What gasket material should you use on sheet metal flanges for ventilation systems

What gasket material to use on sheet metal flanges for ventilation systems

Jocelyn Vachon - VP B.Dev / Product Specialist



Gasket materials require to be compressed, in order to achieve a seal. What materials should you use when flanges are simply made of thin sheet metal?

Ventilation systems assembled on-site require gaskets between sections. Sheet metal flanges cannot create a high, evenly dispersed mechanical load on gasket materials, even if internal pressures are low (6 to 12 inch of water on average).  Here are a few suggestions:

  • Closed cell sponges with a durometer of 20 to 60 (shore 00 scale) are good options
  • Neoprene-based sponges (Robco SC-41 soft / SC-42 medium / SC-43 firm) are the most popular. Self-adhesive strips can be formed (round flanges) or cut in lengths (square flanges) for a quick and wasteless assembly
  • PTFE saturated woven glass tapes (Robco GW-305) can be used where temperatures are above 250°F (130°C) and where a non-combustible material is required
  • Silicone sponge, Jointex expanded PTFE or ceramic paper (Robco 630, 990) can also be considered for more demanding applications (pressure, temperature and/or media).

Communicate with Robco if you need to learn more about the particular conditions of your application.



Quel matériel doit-on utiliser comme joint sur les brides en tôle des conduits de ventilation ?

Par Jocelyn Vachon - VP Dév. Affaires / Spécialiste de produits

 


Les matériaux de joints d’étanchéité demandent d’être compressés, pour créer une zone étanche. Quels matériaux doit-on utiliser lorsque les brides sont simplement faites de tôle mince?

 Les systèmes de ventilation assemblés sur place requièrent des joints entre les sections de conduits. Les brides en tôle ne peuvent pas distribuer de façon uniforme une charge mécanique élevée, même si la pression interne est minime (6’’ à 12’’ d’eau en moyenne).  Voici quelques suggestions :

  • Caoutchoucs en éponge à cellules fermées avec un duromètre de 20 à 60 (échelle shore 00) sont une première option. Des bandes auto-collantes sont formées (brides rondes) ou coupées en longueurs (brides carrées) pour un assemblage rapide et sans perte
  • Les caoutchoucs éponges à base de néoprène (Robco SC-41 souple / SC-42 medium / SC-43 ferme) et l’uréthane micro-cellulaire sont les plus populaires
  • Les bandes de fibres de verre tissées et enduites de PTFE (Robco GW-305 / GW-605) peuvent être utilisées lorsque la température est au-delà de 250°F (130°C) et qu’un matériel non-combustible est requis
  • De l’éponge de silicone, du PTFE expansé Jointex ou du papier céramique (Robco 630, 990) peuvent aussi être considérés pour des applications plus exigeantes (pression, température ou media).

Communiquez avec Robco si vous désirez en apprendre plus sur les particularités de vos utilisations


Comments

Popular posts from this blog

Which Removable Insulation Cover Materials to chose?

Flexible, removable insulation covers find application in heavy industries where swift or regular access to equipment is essential. These covers are crucial for insulating heat (or cold) to ensure safety, energy efficiency, and precision in industrial processes. A common inquiry revolves around the choice of fabric under specific circumstances. One pivotal factor to contemplate is whether the material is in direct contact with the equipment or exposed to external elements.   Presented below is a Decision Table to assist you in making informed choices:   Link We hope this table will facilitate your choice next time you require flexible removable cover insulation. Call Robco or Prodimax if you need further information.

Que signifie "Fire-Safe" pour le choix d'un joint d'étanchéité ?

 Dans le processus de sélection des matériaux de joints, de nombreuses questions portent sur le terme "sécurité incendie". Examinons brièvement les deux méthodes d'essai au feu les plus couramment utilisées pour les joints : API 6FA ET API 607. API 6FA : Le test 6FA-re de l'American Petroleum Institute est utilisé pour qualifier les vannes destinées aux procédés chimiques. La bride est assemblée selon les procédures de boulonnage appropriées et tous les paramètres tels que la contrainte et le couple sont enregistrés. Des thermocouples sont montés à 1 pouce de l'extérieur de la bride (figure 1). La vanne est enveloppée d'une flamme à l'aide de quatre brûleurs au propane disposés symétriquement autour de l'extérieur de la bride. La température de la flamme doit être comprise entre 1400ºF et 1800ºF (moyenne des deux thermocouples) pendant une période de combustion de 30 minutes à partir de l'allumage. La température est maintenue et aucune valeur n...

What does Fire-Safe mean when choosing a Gasket?

  In the process of gasket material selection, many inquiries point to the term “fire-safe”. Lets briefly look at the two most commonly used gasket fire testing methods: API 6FA & API 607. API 6FA: The American Petroleum Institute’s 6FA-re test is used to qualify valves for chemical process service.  The flange is assembled using proper bolt-up procedures and all parameters such as stress and torque are recorded. Thermocouples are mounted 1” away from the outside of the flange (Figure 1). The valve is enveloped in flame using four propane burners arranged symmetrically around the outside of the flange. The flame temperature should be 1400ºF to 1800ºF (average of the two thermocouples) for a burn period of 30 minutes from ignition. The temperature is maintained with no reading less than 1300ºF. An internal water pressure amounting to 75% of the flange rating is applied throughout the test and the leakage rate is continually measured. The test rig is then allowed t...